Primer Melting Temperature (Tm)

If you are endeavouring to design your own primers, always bear in mind that the forward and reverse primer Tms should not be too far apart from one another. Generally, you should aim to have them the same or keep the difference within 2-4 degrees. A way to calculate the primer Tm of your forward and reverse primer sequences is to remember:

A = ~2 degrees
T = ~2 degrees
G = ~4 degrees
C = ~4 degrees

For instance:

Forward: CCGTACATTCGGACATGAGG = C(5x4)+G(6x4)+T(4x2)+A(5x2) = 20+24+8+10 = 62

Reverse: TTGCAAGCTTAAGGCTGACC = C(5x4)+G(5x4)+T(5x2)+A(5x2) = 20+20+10+10 = 60


The ideal PCR annealing temperatures to test should be 2-5 degrees below the primer with the lowest Tm. In this case, the reverse sequence has the lower Tm. When optimizing for the annealing temperature of a PCR, you would in first instance try 55, 56, 57, 58 and 59 degrees.

Tuesday, 9 February 2016

Things To Consider When Ordering Published Primer Sequences

When you see a set of primers in the materials and methods section of a journal publication, it is tempting to order the sequences provided. Before doing so, it is good practice to check the primer sequences to make sure that they are suitable for your needs. In other words, make sure the primer sequences published are suitable for your needs in regards to:

* Cell type – some cell types may have little to no expression of your GOI.
* Tissue type – as with cell type, there may be little to no expression of your GOI.
* Species and percent homology if the species are different.
* Whether the region targeted in the transcript will give you the expected product size when PCR products are run on a gel.
* Primer direction – sometimes the primer sequences provided in a journal article may not be in the correct format for ordering. For instance, if a reverse sequence rather than the reverse complement sequence is provided in the publication, you will have serious issues when you start experimenting with the primers.
* Purpose of the primer – it is important to see what experiments the sequences published were actually used for. A primer set used for expression cloning will not be suitable for real-time PCR.

* The primer sequence published – you want to make sure that the sequences provided are accurate so check by blasting the sequence. It is not uncommon for authors to make typos when entering in their sequences during manuscript preparation.  

Sunday, 3 January 2016

Gene Expression?

A very quick way to determine if a particular gene is expressed in your cells or tissue of interest is via LSBM.


RefExA contains gene expression data derived from microarray analysis of normal human tissues and cultured cell-lines. If you are ever wondering what cDNA template to use to test your new primers, it is worthwhile checking out RefExA to see if the tissue or cell type your template is derived from does express your GOI and to what extent. Sometimes a failed PCR may just be because the template of choice has little to no expression of your GOI.

Screen capture of ESR1 data from LSBM

PCR Tips & Tricks

Most of you are probably aware of the common variations and tweaks you can do to optimize a PCR reaction, such as changing the MgCl2 concentrations. But if you are needing to amplify something tricky, such as a transcript with high GC content for cloning, PCR optimization can become a nightmare.

Tip #1 – Re-amplification
When a nested PCR is out of the question, a re-amplification works just as well. The principle is similar to a nested PCR in that you are enriching the region of interest.

Simply run your PCR reaction in a thermocycler for 10-15 cycles and take 0.5ul of the completed reaction to use as template for a second set of reactions.

Tip #2 – Ramping
In some instances where it is difficult to get your primers to hybridize to the correct complementary sequence of your template (e.g. when amplifying a GC rich region, cloning cDNA that has GC or AT strings, etc), a great technique to try is to lower the ramping speed from the denaturation to annealing steps as well as the annealing to extension steps.


The ramping speed is the time it takes for the thermocycler to heat/cool the reaction to a different temperature i.e. to go from 95 degrees to 60 degrees. For instance, by lowering the ramping speed from 100% to 20% you are essentially giving your primers time to hybridize to their complementary sequences on the template. The principle underlying this technique was inspired by the oligo-annealing step of an EMSA protocol.